The UV-120-1 Pentek UV System has been discontinued by the manufacturer

SKU
PENTEK-UV-120-1
Price $510.99
Availability: Out of stock
Fits standard 3/4-inch water lines
  • Germicidal doses of high-intensity, ultraviolet light
  • Kills bacteria, viruses and other microbiological organisms
  • A carbon block prefilter in a separate housing can be added for cyst reduction.
  • Includes the housing, UV control module with mounting bracket, quartz sleeve, lamp, wrench.
See more product details
The UVBB-120-1 UltraViolet Water Purification System is a self-contained 8 gallon-per-minute system completely ready for you to use. It provides protection from occasional intrusion by microbial contaminants, including protozoan cysts, bacteria and viruses. During ultraviolet sterilization, the water is exposed at a controlled rate to UV light waves, which deactivate the DNA of microorganisms, preventing them from reproducing. For optimum performance, replace the UV bulb every 9-12 months. A cyst reduction carbon block pre-filter (housing and cartridge sold separately) is recommended for reduction of particulates, cysts and chlorine prior to ultraviolet purification to make the UV treatment more effective.
Package Qty 1
Used In Brands Pentek
Manufacturer's Id UV-120-1
UPC 775600425217
Actual Size (in) 25 1/2 inches (length) x 5 1/2 inches (width)
Actual Size (cm) 64.77 x 13.97
Materials of Construction Cap: Polypropylene, Housing: Polypropylene, UV Sleeve: Quartz, Reaction Chamber: Stainless Steel, O-Ring: Buna-N
Filter Life (months) 12 months
Operating Temperature (°F) 40 - 100
Operating Temperature (°C) 4.4 - 37.8
Flow Rate (gpm) 8.00
Flow Rate (lpm) 30.28
Fitting Size (inches) 3/4 inch
Includes Filter Housing, UV Control Module with Mounting Bracket, CBU-10 Filter, Quartz Sleeve, Lamp, Wrench, O-ring, Instructions

The PENTEK-UV-120-1 is comparable with the following part numbers

163007
UV-120-1

User Guide

Instructions

  1. For installation on cold water lines. Do not install where system is exposed to direct sunlight
  2. Allow a minimum of 12-inches clearance under the filter for changing the cartridge and above the system to allow the UV bulb to be changed
  3. Protect against freezing to prevent cracking of the system and water leakage
  4. Do not look directly at the UV lamp. This can cause retina/eye damage
  5. Turn off all electrical power to the system by unplugging or throwing the circuit
  6. Unscrew the UV control module from the mounting bracket (4 screws)
  7. Slide the old bulb out and unplug from the control module. NOTE: Hold the UV lamp only by the plastic covered ends of the bulb
  8. Carefully discard the old UV lamp
  9. Holding the new UV lamp only by the plastic covered ends of the bulb, plug the new UV lamp into the control module or power cord. Slide the new bulb into the cartridge housing and reattach UV control module or secure mounting bracket retainer
  10. Restore electrical power to unit and check for leaks

Reset Instructions